Alarm Codes
In the event of an error, the green LED on the main board will flash one or two times, followed by a series of red flashes. The
pattern repeats until the alarm is cleared.
CodeCode
CodeCode
Code
ErrorError
ErrorError
Error
1 red, 1 green position error exceeds fault limit
2 red, 1 green ccw limit
2 red, 2 green cw limit
3 red, 1 green drive internal temperature exceeds 85°C
3 red, 2 green motor over temperature
4 red, 1 green power supply voltage is more than 55 VDC
4 red, 2 green power supply voltage is less than 18 VDC
5 red, 1 green over current / short circuit
6 red, 1 green bad commutation(Hall) signal
6 red, 2 green bad encoder signal
7 red, 1 green serial communication error
Connector Diagrams
Applied Motion Products, Inc.
404 Westridge Drive Watsonville, CA 95076
Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544
www.appliedmotionproducts.com