21
SV7 Hardware Manual
920-0012F
12/18/2014
B-
B+
A-
A+
V-
V+
B-
B+
A-
A+
V-
V+
LED Codes
GR=Green
RD=Red
MOTOR DISABLED SOLID GREEN
MOTOR ENABLED GR-GR-GR
MOTOR STALL 1 GR + 1 RD
CCW LIMIT 1 GR + 2 RD
CW LIMIT 2 GR + 2 RD
CAN’T MOVE (DISABLED) 2 GR + 1 RD
DRIVE OVER TEMP 1 GR + 3 RD
VOLTAGE HIGH 1 GR + 4 RD
VOLTAGE LOW 2 GR + 4 RD
OVER CURRENT 1 GR + 5 RD
MOTOR OHMS 2 GR + 5 RD
OPEN MOTOR PHASE 1 GR + 6 RD
BAD ENCODER SIGNAL 2 GR + 6 RD
COMM ERROR 1 GR + 7 RD
GND
+5V OUT
Y COMMON
Y3 / FAULT
Y2 / MOTION
Y1 / BRAKE
X8 / CCWLIMIT+
X8 / CCWLIMIT -
X7 / CWLIMIT -
X7 / CWLIMIT+
Y4 -
Y4+
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
X COMMON
X3 / ENABLE
X5 / CWJOG
X4 / ALARM RESET
ANALOG IN2
ANALOG IN1
X2 / DIR -
X2 / DIR+
X1 / STEP+
X1 / STEP -
GND
X6 / CCWJOG
Serial No
SV
SERVO MOTOR
DRIVER
+
-
grounding
screw
to earth
ground
Be careful not to reverse the wires. Reverse connection will destroy your
driver, void your warranty and generally wreck your day.
If you plan to use a regulated power supply you may encounter a problem with regeneration. If
you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is trans-
ferred back to the power supply. is can trip the overvoltage protection of a switching power
supply, causing it to shut down. We oer the RC050 “regeneration clamp” to solve this problem. If
in doubt, buy an RC050 for your rst installation. If the “regen” LED on
the RC050 never ashes, you don’t need the clamp.
RC050 Regen Clamp