22
BLuAC5 S/Q Hardware manual
920-0049 Rev. C
12/8/2014
BLU
Servo
Drive
IN/OUT 1
DIR+
DIR+
DIR- DIR-
STEP+
STEP-
STEP+
STEP-
Indexer
with
Differential
Outputs
BLU Servo
Master
Encoder
GND
DIR-
DIR+
STEP-
STEP+
GND
B-
B+
A-
A+
Using High Speed Inputs with 12-24 Volt Signals
Most PLCs don’t use 5 volt logic. You can connect signal levels as high as 24 volts to the
STEP and DIR inputs if you add external dropping resistors, as shown below.
• For 12 volt logic, add 820 ohm, 1/4 watt resistors
• For 24 volt logic, use 2200 ohm, 1/4 watt resistors
WARNING: The maximum voltage that can be applied directly to a high speed input
terminal is 5 volts. Never apply high voltage AC to an input terminal.
Connecting to Indexer with Differential Outputs
(includes Applied Motion Si-100 Indexer)
Connecting to a Master Encoder
(for following applications)