16
STM23R Hardware Manual
920-0056C
5/5/2015
Connecting the Digital Output
e STM23R features a digital output labelled “OUT. is output closes to signal
a fault condition.
is output can be used to drive LEDs, relays and the inputs of other electronic
devices like PLCs. e “+” (collector) and “-” (emier) terminals of the output transistor are available at the con-
nector. is allows you to congure the output for current sourcing or sinking.
Diagrams of each type of connection follow.
Do not connect the output to more than 30VDC.
e current through the output terminal must not exceed 80 mA.
Sinking Output
STM23R
5-24 VDC
Power Supply
+
Load
OUT-
OUT+
!
STM23R
5-24 VDC
Power Supply
+
Load
OUT-
OUT+
Sourcing Output
Driving a Relay
STM23R
OUT-
OUT+
1N4935 suppression diode
5-24 VDC
Power Supply
+
relay
OUT+
OUT-