CANopen User Manual
Here is the Command Structure:
Object Type Data Type Access Type PDO Mapping COS Default value
Var UNSIGNED16 wo yes yes 0
0x6041 StatusWord
The read only object “statusword” indicates the current status of the drive. Each bit is
mapped as follows:
MSB LSB
Bit
15
Bit
14
Bit
13
Bit
12
Bit
11
Bit
10
Bit
9
Bit
8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
High-Byte L-Byte
Bit Name Mandatory
0 Ready to Switch On
1 Switch On
2 Operation Enabled
3 Fault
4 Voltage Disabled
5 Quick Stop
6 Switch On Disabled
7 Temperature
8 Manufacturer Specic
9 Remote
10 Target Reached
11 Internal Limit Active
12 Operation Mode Specic
13 Operation Mode Specic
14 Manufacturer Specic
15 Manufacturer Specic
Table 14: Bits in the statusword