920-0025 Rev K
3/5/2015
CANopen User Manual
bursts.
Using the target torque and torque constant from the example above the current draw can
be checked, as shown:
0.3531 Nm
= 5.0443 A
0.07
Nm
A
The resultant current, 5.0443A, is below the 7A continuous current rating of the drive, and
well below the peak current rating of 14A. It is possible for the drive to maintain a current of 7A
indenitely, and peak up to 14A for up to two seconds continuously. Values between 7A and
14A may be held proportionally long.
For more information: see CiA 402 - 2, Prole Torque Mode
Figure 18: Prole Torque Mode
Table 24: Prole Torque Mode Example
Graph Point Target Torque Halt Bit Drive command to Motor
Start T1 0 Ramp torque to T1
A T1 0 Maintain torque at T1
B T1 0 -> 1 Ramp torque to zero
C T1 -> T2 1 -> 0 Ramp torque to T2
D T2 -> 0 0 Ramp torque to zero
E 0 0 Maintain torque at zero