Connecting to a Host Using Ethernet
is process requires three steps
Physically connect the drive to your network (or directly to the PC)
Set the drive’s IP address
Set the appropriate networking properties on your PC.
Note: the following pages are an excerpt from the “eSCL Communication Reference Guide”. For more
information, please read the rest of the guide.
Addresses, Subnets, and Ports
Every device on an Ethernet network must have a unique IP address. In order for two devices to communicate
with each other, they must both be connected to the network and they must have IP addresses that are on the
same subnet. A subnet is a logical division of a larger network. Members of one subnet are generally not able
to communicate with members of another unless they are connected through special network equipment (e.g.
router). Subnets are dened by the choices of IP addresses and subnet masks.
If you want to know the IP address and subnet mask of your PC, select Start…All ProgramsAccessories…Com-
mand Prompt. en type “ipcong” and press Enter. You should see something like this:
If your PCs subnet mask is set to 255.255.255.0, a common seing known as a Class C subnet mask, then your
machine can only talk to another network device whose IP address matches yours in the rst three octets. (e
numbers between the dots in an IP address are called octets.) For example, if your PC is on a Class C subnet
and has an IP address of 192.168.0.20, it can talk to a device at 192.168.0.40, but not one at 192.168.1.40. If
you change your subnet mask to 255.255.0.0 (Class B) you can talk to any device whose rst two octets match
yours. Be sure to ask your system administrator before doing this. Your network may be segmented for a rea-
son.
Your drive’s IP Address is stored internally in nonvolatile memory. e factory default address is 10.10.10.10.
is address can be changed using our ST Congurator soware. See Edit IP Address Table under the Drive
menu.